PV-Mover dual-axis Photo-Voltaic-Mover

Follow the path of the sun!

 

• Module carrier - variants

 

The module carrier is individually manufactured for each case of application.
That means: The entire spectrum of all Solar Power-modules available at the market can be used. The framework width and length determine the number of module rows. The PV-modules are laterally introduced and locked to 8m/12m special profiles. No additional screw connection of the module framework is necessary, which means that assembly is fast and simple. Pin-riveted or secured screwed angle profiles on the sides protect the module rows from theft. Cross-wind bonds provide stability to the entire construction. The module carrier profiles are galvanized or made of aluminum and are develivered as prefabricated assembly packages.

The adjusted total output of a mover is approx. 6-21 kWp. Custom-made variations can be realized at the customer´s request at short notice. New PV-module types are introduced to our current range at short notice.

 

• Control – communication – sensor technology - security              

 

By using both a local PV controller (PVlocal) and a central control station (PVleitstand), Löseke & Marx are able to supply a radio-controlled system, which provides the overall control functions for the general operation of synchronized continuous and demo working modes (e.g. for commissioning) and has been specifically designed to operate as a completely self-sufficient system.

The central PVcontrol station can be optionally expanded into a PCsuite, which includes a PV monitor that can be used to supervise the power generation as well as to maintain all of the functions needed with regard to running a professional maintenance management system.
The controller uses microprocessor-based circuits, which have been optimized to fulfill the project definition requirements. National as well as international Support is guaranteed by our extensive service organization, starting with the installation and the commissioning and covering all of the servicing while the plant is running.

This support not only covers the control system but also the additional services needed for maintaining a photovoltaic park’s infrastructure, such as the power electronics, Internet connection, remote servicing and other specific requirements such as a proactive reporting system.                                 

 

Functions of the PVlocal controller


In addition to various monitoring functions, the controller’s other basic functions are:

  1. Calculating the daily program, which depends on the date, the longitude and the latitude
  2. Regular autonomous adjustment checks
  3. Changing between the two synchronized operating modes
    • a) live mode, and
    • b) trial mode with up to 12 day-cycles in one calendar day
  4. Customized operation available thanks to a variety of parameters.
  5. Integrated dynamic motor monitoring for the protection of the mechanical system
  6. Precision through a high-speed monitoring system
Each of the local PV controllers can also work as an optional wind measuring station, which means that the customer is free to decide how many wind monitors he wants to have in his park. Parameters such as time constants, storm angle and the wind speed limit settings are used to control the local PV monitoring system and monitor the wind conditions. In case of a storm, the results are broadcast to the other controllers, and each local controller also communicates the switch to another mode to the central PVleitstand. At present, there are no known limits for parallel operation of this solution and the technology works successfully with several thousand remote units running in parallel.

 

The system automatically creates a dynamic meshed network in order to increase the operating safety of the system, and this ensures that a complete network chain does not drop out if a single unit fails.
The local PV controller will be optimized to match the park requirements and parameters, and it will also undergo a long-term quality assurance line test before the batch is delivered. Special test circuit boards simulating a complete PV Mover were developed for this purpose, just so that commissioning times are reduced to a minimum while maximizing safety. A complete replacement of a controller is nevertheless simple and quick, should a controller still react in any unexpected way.
All functions are integrated in a very robust casing.

 

Each of the local PV controllers sends messages to the PCsuite, so that the current park status is always displayed on the computer screen.

 

PVleitstand    (central controller)

PVleitstand is the central controller and forms the basis for the monitoring. Standard delivery includes a clear diagram showing the last status messages of the PVlocal. Due to the self-sufficient nature of the PVlocals, the central unit only updates the time in the local units during operative mode.  

 

The concept of the system is like a database and stores the current parameters of each PVlocal with respect to ACTUAL and TARGET values. The set-up also allows for individual evaluations to be made.                   
The installation of the software should be made on a remotely accessible normal PC or industry computer, so that observation and control of the PVlocals and therefore the complete park can be done via the internet.


The standard functions are                  

1.Actualization of the parameters of the PVlocals
2.Storing the status messages of the PVlocals
3.Actualization of the firmware
4.Changing the operative modes

 

PV-Monitor

The optional PV-Monitor provides, apart from numerous optional diagrams including calling up the daily program, also the possibility of making evaluations available to potential investors, tailored to their investment needs. This includes productive data of those electronics which are accessible via a computer hook-up. The exchange of data with the computer system of a potential investor (eg their own local PV-Monitor) would be done via the internet.     

 

PV-Maintenance

The optional PV-Maintenance rounds off the product family and offers, along with numerous optional diagrams, the opportunity of monitoring individual objects of the park – from the motors of the individual movers to the lawn mower. Work details can for example be given for maintenance and upkeep can be lodged or called up. The operator can organize maintenance and service efficiently; he can monitor it and reduce it to a minimum effort.                   
The data exchange with external systems (local PV Monitor) of, for example an investor, would be made via the internet.    
                    

Summary:    

The electronic components of the PV Mover cover all typical requirements and interests of the park operator and of potential investors. The data transfer with radio signals reduces costs drastically while increasing security and profits significantly, since a vulnerable bus cabling system is not needed. Animals or other environmental influences cannot hinder controlling.

PV-Mover M120-S

dual-axis on concrete
foundations up to
120sqm module surface

PV-Mover S45-R

dual-axis adjusted
on 3m tubing column

PV-Mover S45-C

dual-axis adjusted near
-surface field installation

PV Mover M100

PV Mover M100
New Generation

PV Mover M100

PV Mover M100
New Generation

PV Mover M100

PV Mover M100
Newe Generation

PV Mover M100

PV Mover M100
New Generation

PV Mover M100

PV Mover M100
New Generation